File INDEX

Directory of image this file is from
This file as a plain text file

*20
	 
	 
/INDEX
	 
	 
/SUMMARY LIST OF INSTRUCTION SOURCE
/  LISTINGS FOR THIS MAINTENANCE TAPE
/  ACCUMULATED INTO A SINGLE LISTING
/
/NOTE THAT BINARIES LOCATED PAST
/   BLK 1000 MAY NOT BE LOADED BY DIAL
/   TILL THEY ARE MOVED BY PIP TO A
/   LOCATION BELOW BLK 1000
	 
	-	-	-	-	-	-
/PIP
	PERIPHERAL INTERCHANGE PROGRAM
	 
	STARTING ADDRESS
	LOCATION 20
	 
	 
	-	-	-	-	-	-
	 
/MARK12
	DEC-12-YITA
	 
	MARK12 A FORMATING AND
	VERIFICATION PROGRAM FOR
	UNCERTIFIED TAPES
	   (VERSION 0)
	 
	STARTING PROCEDURE
	IF THE VERSION OF DIAL USED
	DOES NOT AUTOMATICALLY START
	THAN MARK12 IS STARTED BY THE
	FOLLOWING PROCEDURE:
	 
	1. BE SURE PROSCESSOR IS STOPPE;
	MOMENTARILY PRESS THE STOP
	SWITCH IF NECESSARY.
	 
	2. PRESS I-O PRESET WITH THE
	MODE SWITCH SET TO LINC.
	 
	3. PRESS START 20.
	 
	 
	-	-	-	-	-	--	
	 
	 
/RIMLDR
	DEC-08-LRAA-D
	 
	READ-IN-MODE LOADER
	 
	STARTING ADDRESS
	LOCATION 7756
	 
	 
	-	-	-	-	-	-	-
	 
/BINLDR
	 
	DEC-08-LBAA-D
	 
	BINARY LOADER
	 
	STARTING ADDRESS
	LOCATION 7777
	 
	 
	-	-	-	-	-	-	-
	 
/CBL
	 
	MAINDEC-08-D1L0
	 
	BASIC PDP-8 MEMORY CHECKERBOARD
	BASIC PDP-8I MEMORY CHECKERBOARD
	 
	STARTING ADDRESS
	LOC. 0005  LOW END CHECKERBOARD
	LOC. 7430  HIGH END CHECKERBOARD
	 
	SWITCH SETTINGS
	SR 0100  STANDARD PDP-8 CORE
	SR 0101  STANDARD PDP-8I CORE
	ALSO SR 0000 AND SR 0001 ARE FOR
	SPECIAL CORE UNITS
	 
	 
	-	-	-	-	-	-	-
	 
/CBH
	 
	MAINDEC-08-D1L0
	 
	BASIC PDP-8 MEMORY CHECKERBOARD
	BASIC PDP-8I MEMORY CHECKERBOARD
	 
	STARTING ADDRESS
	LOC. 0005  LOW END CHECKERBOARD
	LOC. 7430  HIGH END CHECKERBOARD
	 
	SWITCH SETTINGS
	SR 0100  STANDARD PDP-8 CORE
	SR 0101  STANDARD PDP-8I CORE
	ALSO SR 0000 AND SR 0001 ARE FOR
	SPECIAL CORE UNITS
	 
	 
	-	-	-	-	-	-	-
	 
	 
ADDRSLO
	MAINDEC-08-D1B0-D
	 
	MEMORY ADDRESS TEST
	 
	STARTING ADDRESS
	LOC. 0000  LOW STORAGE
	LOC.7400  HIGH STORAGE
	 
	SWITCH SETTINGS
	SR0 = 1  HALT AFTER ERROR
	 
	 
	 -	-	-	-	-	-	-
	 
ADDRSHI
	 
	MAINDEC-08-D1B0-D
	 
	MEMORY ADDRESS TEST
	 
	STARTING ADDRESS
	LOC. 0000  LOW STORAGE
	LOC.7400  HIGH STORAGE
	 
	SWITCH SETTINGS
	SR0 = 1  HALT AFTER ERROR
	 
	 
	-	-	-	-	-	-	
	 
	 
ADDRS12
	NO SOURCE FOR ADDRS12
	 
	 
	-	-	-	-	-	-	-
	 
	 
RANISZ
	MAINDEC-08-DO7B-D
	 
	RANDOM ISZ TEST
	 
	STARTING ADDRESS
	LOC. 0037
	 
	SWITCH SETTINGS
	SR0 = 1 HALT ON ERROR
	SR1 = 1 ELIMINATE ERROR PRINTOUT
	SR3 = 0 RANDOM FROMS
	SR3 = 1 FIXED FROMS
	SR4 = 0 RANDOM TOS
	SR4 = 1 FIXED TOS
	SR5 = 0 RANDOM OPERAND
	SR5 = 1 FIXED OPERAND
	SR9 = 1 DO ONE ISZ ONLY
	SR11= 0 DO PART 1
	SR11= 1 DO PART 2 (SR3 SR4 SR5  MUST BE ZEROS)
	 
	 
	-	-	-	-	-	-	-
	 
	 
RANJMP
	MAINDEC-08-DO4B-D
	 
	RANDOM JMP TEST
	 
	STARTING ADDRESS
	LOC. 0200
	 
	RESTART ADDRESS
	LOC. 0214
	 
	SWITCH SETTINGS
	SR0 = 1 HALT ON ERROR
	SR2 = 0 SELECT RANDOM JUMP FROM ADDRESS
	SR2 = 1 HOLD JUMP FROM ADDRESS  CONSTANT.
	SR3 = 0 SELECT RANDOM JUMP TO   ADDRESS.
	SR3 = 1 HOLD JUMP TO ADDRESS    CONSTANT.
	 
	 
	-	-	-	-	-	-	-	-	
	 
JMPJMS
	 
	MAINDEC-08-DO5B-D
	 
	RANDOM JMP-JMS TEST
	 
	STARTING ADDRESS
	LOC. 0200
	 
	RESTART ADDRESS
	LOC. 0215
	 
	SWITCH SETTINGS
	SR0 = 1 HALT ON ERROR
	SR2 = 0 SELECT RANDOM FROM ADDR-ESS.
	SR2 = 1 HOLD THE FROM ADDRESS   CONSTANT.
	SR3 = 0 SELECT RANDOM TO ADDRESS
	SR3 = 1 HOLD TO ADDRESS CONSTANT
	 
	 
							
	 
	 -	-	-	-	-	-	
	 
	 
JMPSELF
	MAINDEC-12-D1BA
	 
	JMP SELF
	 
	STARTING ADDRESS
	START 20
	 
	SWITCH SETTINGS
	SR00 = 1 SUPPRESS HALT; DEPRESS CONTINUE FOR PRINTOUT OR LOOP.
	SR01 = 1 SUPPRESS TYPING
	SR02 = 1 SCOPE LOOP ON ERROR
	ALSO SET SR9 SR10 AND SR11 TO   THE NUMBER OF THE MEMORY BANK YOU WISH  TO TEST. THIS WOULD BE 000 FOR BASIC 4K.
	 
	 
	-	-	-	-	-	-	-
	 
	 
MEMDATA
	MAINDEC-12-DIEA-D
	 
	FLOAT 0NES AND ZEROS THROUGH MEM
	 
	STARTING ADDRESS
	START 20
	 
	SWITCH SETTINGS
	SR00 = 1 SUPPRESS HALT
	SR01 = 1 SUPPRESS TYPING
	SR02 = 1 SCOPE LOOP ON ERROR
	ALSO SET SR9 SR10 AND SR11 TO   THE NUMBER OF THE MEMORY BANK YOU WISH  TO TEST. THIS WOULD BE 000 FOR BASIC 4K.
	 
	 
	 
	-	-	-	-	-	-	-
	 
INST1
	 
	MAINDEC-8I-DO1C
	 
	INSTRUCTION TEST 1
	 
	STARTING ADDRESS
	LOC. 144
	 
	SWITCH SETTINGS
	SET SR = 7777
	 
	 
	-	-	-	-	-	-	-
	 
INST2
	 
	MAINDEC-8I-DO2B
	 
	INSTRUCTION TEST 2
	 
	STARTING ADDRESS
	LOC. 201
	 
	 
	 
	 
	-	-	-	-	-	-	-
	 
	 
INST2A
	08-D01A-D
	 
	PDP-8 INSTRUCTION TEST - PART 2A
	 
	ST ADD
	LOC 1200
	 
	SW SET
	SET LSW = 7777 BEFORE ST PROGRAM
	 
	 
	 
	-	-	-	-	-	-	-	
	 
	 
	 
INST2B
	08-D02B
	 
	PDP8 INST TST PART 2
	 
	ST ADD
	LOC 0200 TWOS ADD TST
	LOC 2000 ROTATE TST
	 
	SW SET
	SW0 STOP ON ERR
	SW1 SCOPE MODE
	SW2 PRINT ERROR
	SW3 LEAVE TWOS ADD TST ST ROTATE
	ALSO MAY USE COMBINATIONS SW0-2
	 
	 
	 
	-	-	-	-	-	-	-	
	 
	 
TC12DAEX
	 
	MAINDEC-12-D3DB-D
	 
	PDP-12 TAPE DATA EXERCISER
	 
	ST ADD
	LINC MODE LOC 200
	 
	SW SET
	RSW 0=1 DEL ERR HLTS AND RESTART CURRENT PASS
	RSW 1=1 DELETE ERR MESSAGES
	RSW 6-8=NUM OF EXTRA TAPE TRANSPORTS THAN 1
	RSW 9-11=NUM EXTRA 4K MEMORY FIELDS
	 
	SET UP
	MOUNT TAPE ON DRIVES TO BE TESTED
	SET UNIT SEL ST FROM 0 AND INC
	SET REMOTE AND WRITE ENABLE
	 
	ANALOG CH 0-4 CONTROL DISPLAY
	  
	 
	 -	-	-	-	--	-	-	
	 
	 
MEMCT
	 
	12-D1FA
	 
	PDP-12 BASIC MEMORY CONTROL TEST
	 
	ST ADD
	LOC 20
	 
	SW SET
	SR00=1  INHIBIT ERR HLT
	SR01=1  INHIBIT ERR PRINTOUT
	SR02=1  SCOPE LOOP ON FAILING ROUTINE
	SR03=1  SCOPE LOOP ON NON-FAILING ROUTINE
	SR05=1  INHIBIT BELL
	SR06=1  INHIBIT PASS CNTR PRINTOUT
	 
	P-MODE
	I-O PRESET
	START LOC 20
	 
	 
	 
	-	-	-	-	--	-	
	 
CPTST1
	 
	12-DOBA
	 
	INST TST PART 1
	 
	STARTING ADDRESS
	START 20
	 
	SWITCH SETTINGS
	LEFT SW = 7777
	RT SW   = 7777
	SENS SW = 77
	 
	 
	 
	-	-	-	-	-	-	-
	 
	 
CPTST2
	 
	12-D0AB
	 
	PDP-12 CP TST 2
	(SKIP AND DATA HANDELING)
	 
	STARTING LOCATION
	START 20
	 
	SWITCH SETTINGS
	SENSE SW = 77 INITIALLY AND THEY SHOULD BE SET TO ZERO ONE AT A TIME TO BE CERTAIN THAT THEY WILL CAUSE ERR HLTS
	 
	 
	 
	-	-	-	-	-	-	-
	 
CPTST3
	 
	 
	12-D0CB
	 
	11-15-71
	 
	PDP-12 CP TEST 3
	 
	ST ADD
	8-MODE START 400
	 
	SW SET
	RSW5=0 A SYSTEM
	RSW5=1 B OR C SYSTEM
	 
NOTE: I BELIEVE THIS BINARY DOES NOT RUN RIGHT.  DAO, 5/5/75
	 
	 
	-	-	-	-	-	-	-
	 
TTY1
	 
	 
	08-D2PE
	 
	FAMILY-OF-8 ASR 33 OR 35 TELE-  TYPE TESTS PART 1
	 
	STARTING ADDRESS
	LOC 200
	 
	SWITCH SETTINGS
	SR0 HALT AT END OF ROUTINE
	SR1 SELECT ROUTINE WHOSE NUMBER IS IN SR6-11
	SR6-11 ROUTINE NUMBER SELECTED
	 
	 
	 
	-	-	-	-	--	-	
	 
TTY2
	 
	 
	08-D2QD
	 
	TELETYPE TESTS
	 
	ST ADD
	LOC 200
	 
	SW SET
	PROG 0-3
	SR0 HLT END ROUT ROUT NUM IN AC
	SR1 SEL ROUT SR6 TO SR11
	SR2 LOOP PRG
	SR6 TO SR11 SEL ROUT
	ALSO
	PRG1 3 6 7 10
 	SR5=1 HLT ON ERR BAD CHAR IN AC
	SR5=0 HLT END DATA BK ERR CNT AC
	 
	 
	-	-	-	-	-	-	-
	 
	 
TC12F
	 
	MAINDEC-12-D3EB
	 
	TC 12-F OPTION
	 
	JULY 1 1970
	 
	ST ADD
	START 20 KEY
	 
	SW SET
	RSW 0 = 0  HLT ON ERROR
	RSW 1 = 0  PRINT ERROR MESSAGE
	 
	 
	 
	----	-	-	-	-	-	-	-
	 
M08DGMCA
	 
	 
	 
	 
	MAINDEC-08-DGMCA-A
PDP-8,	8I,8S EXTENDED MEMORY CONTROL
	REPLACES: MAINDEC-08-DIGD-PB
	1970,  1973
	RECEIVED ON PAPER TAPE
	 
	 
	-	-	-	-	-	-
	 
	 
M12-D6BC
	MAINDEC-12-D6BC
	8/1/71
	VR14 AND VR20 DISPLAY TEST
	1971
	 
	 
	 
	-	-	-	-	-	-	
	 
	 
EXTMC
	08-D1GD
	 
	EXT MEMORY CONTROL
	 
	ST ADD
	LOC 200
	 
	SW SET
	SR8=1 IF PDP-8I
	SW8-0 IF PDP-8 OR 8S
	SR9 10 11 MUST CONT AN OCTAL VAL
	EQUAL TO THE NUM OF EXT MEM FLDS
	AVAILABLE(1 TO 7) NOTE FLD ZERO 
	IS NOT INCLUDED IN THIS VALUE
	 
	 
	-	-	-	-	-	
	 
EXTAT
	 
	MAINDEC-8-D1HA
	 
	PDP-8 8I EXTENDED MEMORY ADDRESS TEST
	 
	MARCH 13 1968
	 
	OPERATING PROCEDURE
	LSR=200
	8-MODE
	PRESS ST LEFT SW
	TTY PRINTS  TEST LIMITS
	SPECIFY LIMITS VIA KEYBOARD
	TTY PRINTS  SETUP SR
	SET RSW TO 0000
	SW SET
	SR0=1  HLT AFTER TST OR ERR
	SR1=1  INHIBIT ERR PRINTOUT
	SR2=1  BELL ON ERR
	SR3-6  SEL TST
	SR9=1  INHIBIT PROG RELOCATION
	SR11=1 CHANGE LIMITS
	 
	 
	 
	-	-	-	-	-	-	
	 
	 
EXTCB
	 
	08-D1EB
	 
	EXT MEM CHECKERBOARD
	 
	ST ADD
	LOC 200
	 
	REST ADD
	LOC 207
	 
	SW SET
	TST LIM TYPEOUT SR=0000 NORMALLY
	SR0 HALT AFTER TST OR ERR
	SR1 INHIB ERR PRINTOUT
	SR2 BELL ON ERR
	SR3-6 TST SEL
	SR7 INH PRG RELOCATION
	SR11 PRG AUTO REST LOC 207 ALLOW
	TST LIM AND SR TO BE CHANGED
	 
	 
	-	-	-	-	-	-	
EXTMC12
	 
	 
	 
	12-D1AC
	 
	PDP-12 EXT MEM CONTROL TST
	 
	ST ADD
	LOC 200
	 
	 
	 
	 -	-	-	-	-	-	
	 
	 
M08-D1EC
	MAINDEC-08-DIEC
	NOVEMBER 1, 1971
	PDP-8 & 8I EXTENDED MEMORY CHECKERBOARD
	 
	SET RSW = 0200
	SET LSW = 0000
	8-MODE START LSW
	 
	TEST LIMITS ARE 0,1 FOR 8 K MEMORY
	CARRIAGE RETURN AFTER "SETUP SR"MESSAGE
	 
	 
	  
	 
	-	-	-	-	-	-	
	 
	 
TC12 I
	MAINDEC-12-D3AE-D
	 
	PDP-12 TAPE CONTROL TEST (PART I OF 2)
	 
	ST ADD
	LSW = 200
	RSW = 0
	8 MODE
	I-O PRES
	ST LEFT SW
	 
	SW SET
	SR00 = 1 SUPPRESS ERROR HALTS
	SR01 = 1 SUPPRESS TYPEOUTS RING BELL ON ERROR
	SR02 = 1 SCOPE LOOP ON A FAILING TEST
	SR03 = 1 SCOPE LOOP ON A NON-FAILING TEST
	SR04 = 1 UNIT DOES NOT HAVE EXTENDED TAPE FIELDS
	SR05 = 1 SUPPRESS THE BELL
	 
	 
	-	-	-	-	-	-	
	 
TC12 II
	 
	MAINDEC-12-D3GA
	 
	PDP-12 TAPE CONTROL TEST (PART 2 OF 2)
	 
	ST ADD
	8-MODE LOC 200
	 
	SW SET
	SR00 = 1 SUPPRESS ERROR HLT
	SR01 = 1 SUP TYPE OUTS RING BELL ON ERR
	SR02 = 1 SCOPE LOOP FAILING TST
	SR03 = 1 SCOPE LOOP NON-FAILING TST
	SR04 = 1 1 UNIT DOSE NOT HAVE EXTENDED TAPE FIELDS
	SR05 = 1 SUP THE BELL
	SR06 = 1 SUP THE PASS COUNTER
	 
	NOTE
	SET ONLY 1 TRANS TO 0 AND ALL OTHERS TO DIF NUMS EXCEPT 1
	SET WRITE EN SW TO OFF
	SET ALL TRANS SW TO OFF
	REMOVE ANY TAPES ON TRANSPORT
	 
	 
	-	-	-	-	-	-	-
	 
	 
TAPEDATA
	MAINDEC-12-D3FB
	 
	PDP 12  TAPE DATA TEST
	 
	START ADDRESS
	LOC 20 INST FLD 2
	L MODE
	 
	SW SET
	SNS SW 0 = 1 IGNORE ERROR
	SNS SW 1 = 1 LOOP ON READ WRITE TST
	SNS SW 2 = 1 LOOP ON WRITE PORTION OF TST
	SNS SW 3 = 1 LOOP ON READ PORTION OF TST
	SNS SW 4 = 0 FIXED DATA PATTERN
	SNS SW 4 = 1 RANDOM DATA PATTERN
	SNS SW 5 = 1 LONG SCOPE LOOP TEST
	 
	 
	-	-	-	-	-	-
	 
ADTST
	 
	12-D6CC
	 
	A TO D TST
	 
	ST ADD
	LOC 4020
	 
	SW SET
	SSW=00 CH 00-17 ARE SAM AND DIS
	SSW=40 CH 20-37 ARE SAM AND DIS
	SSW=20 CH SEL BY LSW 7-11
	SSW=10 CH 0-7 
	SSW=04 CH 10-17
	SSW=02.CH 20-27
	SSW=01 CH 30-37
	 
	 
	-	-	-	-	-	-	-
	 
	 
RELAYTST
	12-D8AB
	 
	PDP-12 RELAY REGISTER TEST
	 
	3 PART PROG
	 
	RELAY FLIP FLOP REG TEST
	A. 8 MODE
	B. IF=0 DF=0
	C. IO PRESET
	 
	RSW TO RELAY TST
	A. L MODE
	B. IO PRESET
	C. LSW=1000
	D. ST LS
	E. RSW=0011
	F. ALTER RSW6-11 DATA SHOULD AP-PEAR IN BOTH RELAY REG LAMPS AND AC
	G. RSW0-5 APPEAR BUT NO EFFECT
	 
	RELAY TST
	A. L MODE
	B. IO PRESET
	C. LSW=1003
	D. ST LS
	 
	 
	 -	-	-	-	-	-	-	
	 
	 
DISPTST
	12-D6BB
	 
	VR12 DISPLAY TST
	 
	ST ADD
	LOC 20
	 
	SW SET
	SSW0=1 RETURN TO DIAL MONITOR
	STRIKING F KEY ON TTY DIRECTS   THE PROG TO LOCK ONTO THE CURRENT DIS
	STRICKING ANY OTHER TTY KEY WILL DIRECT THE PROG TO ALTERNATE BETWEEN   THE THREE PATTERNS
	 
	 
	-	-	-	-	-	-	-
	 
KW12A
	 
	MAINDEC-12-D8CD
	 
	12-1-71
	 
	KW12A REAL TIME CLOCK
	 
	ST PROCEDURE
	SET SEL FREQ ON KW12 PANEL TO LINE FREQUENCY
	SL=200
	IF TST AD-12 FAST SAM INST SET KNOB 0 CCW AND KNOB 1 CW
	 
	8 MODE
	IO PRES
	ST LEFT SW
	 
	SW SET
	SR=0000 TST AD-12 FAST SAM
	SR=1000 SUP TST AD-12 FAST SAM
	SR=2000 SUP TYP K EACH PASS
	AR=4000 ALLOWS PROG TO REP IND
	 
	 
	-	-	-	-	--	
M12DAEXA
	 
	 
	 
	MAINDEC-12-DAEXA-A
	PDP-12 SYSTEM EXERCISER
	APRIL 1 1973
	REPLACES: MAINDEC-12-D7CD
	 
	ENTERED FROM PAPER TAPE WHICH NOTES THAT
	MAIN DEC CHANGE NOTICE MAY BE REQUIRED
	FOR PROGRAM TO OPERATE
	 
	NOTE: MAY NOT BE LOADED BY DIAL FROM ITS PRESENT LOCATION AT BLK 1031 ON THIS TAPE
	 
	 
	--	-	-	-	-	-
	 
	 
ONOFF
	08-D1AC
	 
	PDP8 MEMORY POWER ON OFF TST
	 
	ST PROCEDURE
	SL=0014 AND ST LS
	PROG SHOULD HLT AT 0042
	SL=0001 AND ST LS
	PROG SHOULD NOW LOOP
	 
	RESTART LOC 0020
	 
	 
	-	-	-	-	-	-	
	 
	 
RESERVED
	
	THIS SPACE IS RESERVED FOR
	TC12DAEX AND FOR
	M12DAEXA TO WRITE IN
	BOTH OF THESE PGMS WRITE
	ONLY IN BLKS 770--1030
	WHEN THEY ARE RUN.
	HENCE THE REGULAR MAINTENANCE
	TAPE CAN BE LEFT ON THE 
	TRANSPORT SO LONG AS IT HAS
	1600 OCTAL BLOCKS.
	 
	 
	-	-	-	-	-	--	
	 
CB12
	 
	MAINDEC-12-D1DA
	 
	PDP-12 CHECKERBOARD
	 
	OCT 20 1969
	 
	ST PROC
	RSW9-11 SET TO AMOUNT OF MEMORY AVAILABLE IN 1K SEG
	8-MODE
	IO PRESET
	START 20
	 
	SW SET
	SR00=1 SUPPRESS ERR HLT
	SR01=1 SUPPRESS PRINTOUT
	SR02=1 SCOPE LOOP ON FAILING CELL
	SR03=1 LOOP ON SELECTED FIELD
	 
	 
	-	-	-	-	-	-	-	-
	 
	 
M12-D0SA
	 
	MAINDEC-12-D0SA
	KF12B AUTOMATIC PRIORITY INTERRUPT
	RELEASED APRIL 5. 1971
	ENTERED FROM PAPER TAPE WITHOUT APPARENT TROUBLE. 
	 
	 
	NOTE: MAY NOT BE LOADED BY DIAL FROM ITS PRESENT LOCATION AT BLK 1060 ON THIS TAPE
	-	-	-	-	-	-	
	 
M12-D0CB
	MAINDEC-12-D0CB-PB
	 
	CPTST3
	PDP-12 CP TEST III
	NOV 1. 1971
	 
	LSW=0000
	RSW=0100   FOR PDP12B
	8-MODE   START 20
	 
	HALTS ON ERRORS:  NO PRINTOUT
	(THIS VERSION OF CPTST3 WORKS)
	 
	COPIED FROM PAPER TAPE WITHOUT APPARENT TROUBLE
	 
/NOTE:MAY NOT BE LOADEED BY DIAL FROM ITS PRESENT LOCATION AT BLK 1100 ON THIS TAPE
	 
	-	-	-	-	-	-	-
	 
EAE3A
	MAINDEC-8I-DOAA
	 
	PDP-8I INSTRUCTION TEST PART 3A
	 
	STARTING LOCATION
	LOC. 200
	 
	SWITCH SETTINGS
	SR0 = 1 HALT ON ERROR
	SR1 = 1 SCOPE MODE
	SR2 = 1 PRINT ERROR INFO
	SRO AND SR2 = 1
	SR1 AND SR2 = 1
	SR0 SR2 AND SR3 = 1
	SR0 SR1 AND SR2 = 1
---------------------------------------
EAE3B
	8I-DOBA
	 
	EXT ARITH PDP8I INST TST PART 3B
	 
	ST ADD
	LOC 200
	 
	SR0  HLT AFTER CUR ROUT
	SR1  SEL ROUT VIA SR9-11
	SR2  LOOP ROUT
	SR3  LOOP PROG
	SR4  LOCK ON TST
	SR5 = 0 PNT ON ERR
	SR5 = 1 HLT ON ERR
	SR6  HLT AFTER PNT
	SR7  PNT FAIL RATE
	SR8  PNT SIM AND OR SCOPE LOOP
	SR9-11 = NUM OF ROUT SEL
---------------------------------------------
PWRFAIL
	08-D1KA
	 
	KP8I KR01 POWER FAIL TEST
	 
	ST ADD
	LOC 200
	 
	SW SET
	0400 TEST 1 INT AND SKP
	1000 TEST 2 TIME TO STORE REG
	2000 TEST 3 GEN OF IOTS
	0000 TEST 4 STORE ACTIVE REG
	4000 COMPUTER WITH EAE
---------------------------------------
CALCOMP
	08-D6CC
	 
	PDP-8 CALCOMP PLOTTER DIAGNOSTIC
	 
	ST ADD
	LOC 200
	 
	SW SET
	SW0 HLT PROG WHEN DRAW PATTERNS
	SW1 RETRACE OCTAGONS OR CON SQ
	SW2 LOOP TIMING TSTS
	SW3 SET IF 31 INCH PLOTTER
	SW5 SET IF 5 MIL PLOTTER
	SW11 SET IF PDP-8L
---------------------------------------------
SYEX12
	PDP12 SYSTEM EXERCISER
	12-D7CD
	 
	8-1-71
	PDP-12 SYSTEMS EXERCISER
	 
	ST ADD
	PDP-8 MODE
	START 20
	 
	SW SET
	RSW 0 = 1  DEL REC ERR HLTS - RESTART THE CUR PASS
	RSW 1 = 1  DEL ERR MESSAGES
	RSW 2 = 1  INH ST OF LP08-LP12
	RSW 3 = 1  INH ST OF FPP-12
	RSW 4 = 1  INH ST OF RF08-DF32
	RSW 5 = 1  INH ST OF RK08
	RSW 6 - 8  NUM EXTRA TRANSPORTS GREATER THAN 0
	RSW 9 - 11 NUM EXTRA MEM BANKS GREATER THAN 4K
----------------------------------------------
LINEPNTR
	08-D2LA
	 
	645A LINE PRINTER TEST
	 
	ST ADD
	LOC 200
	 
	SW SET
	SW0 REPEAT SECOND PATTERN
	SW1 REPEAT THIRD PATTERN
	SW2 REPEAT FOURTH PATTERN
	SW3 REPEAT FIFTH PATTERN
-----------------------------------------
/END OF INDEX
/LISTING OF DESCRIPTIVE SOURCES FOR
MAINTENANCE BINARIES ON THIS TAPE
	
/KEPT IN THE WORK AREA FOR YOUR CONVENIENCE
	 
	 
	 
	 
	 



Feel free to contact me, David Gesswein djg@pdp8online.com with any questions, comments on the web site, or if you have related equipment, documentation, software etc. you are willing to part with.  I am interested in anything PDP-8 related, computers, peripherals used with them, DEC or third party, or documentation. 

PDP-8 Home Page   PDP-8 Site Map   PDP-8 Site Search