		MAX-MIN DETECTOR  10/10/73

	THE DETECTOR HAS BEEN IMPLEMENTED AS A HARDWARE DEVICE
USING STANDARD OPERATIONAL AMPLIFIERS, FET SWITCHES, AND LOGIC
ELEMENTS. IT ALSO EXISTS AS A FOCAL 12 PROGRAM THAT OPERATES 
ON STORED DIGITAL DATA.

	A MAXIMUM IS DEFINED AS THE LARGEST VALUE PRECEDED BY
A VALID MINIMUM AND FOLLOWED BY A DESIGNATED DROP. SIMILARLY
A MINIMUM MUST BE PRECEEDED BY A VALID MAXIMUM AND FOLLOWED
BY A DESIGNATED RISE. A DESIGNATED DROP IS A FUNCTION OF THE 
SIZE OF A POTENTIAL MAXIMUM PLUS SOME CONSTANT PLUS
ANY OTHER PARAMETER THAT IS CONVENIENT.

THE INFLUENCE OF THE DESIGNATED DROP
	MODIFYING THE RELATIVE IMPORTANCE OF COMPONENTS OF THE 
DESIGNATED DROP ADAPTS THE DETECTOR FOR THE SPECIAL CHARACTERISTICS
OF THE DATA.
	1. A SMALL CONSTANT PLUS 80% OF THE POTENTIAL MAXIMUM-THE
DETECTOR IS NOW MORE SENSITIVE OT SMALL PEAKS NEAR THE BASELINE
THAN LARGE PEAKS. THIS IS A CHARACTERISTIC SUITABLE FOR ANALOG
OUTPUT FROM SCANNING MASS SPECTROMETERS. IF THE CONSTANT
WERE NOT PRESENT THE SYSTEM WOULD BBECOME TOO SENSITIVE
AND BEGIN TRIGGERING ON BASELINE NOISE.

	2. A CONSTANT ALONE -THE DETECTOR IS NOW INDEPENDENT OF
ANY FIXED BASELINE.EVERY MINIMUM IS THE REFERNCE LEVEL FOR A 
POTENTIAL MAXIMUM AND VICE VERSA. THIS CHARACTERISTIC IS 
SUITABLE FOR USE WITH ANALOGS OF BLOOD PRESSURE AND THE 
ELECTROCARDIOGRAM.

       WRITE 5 LINES

       WRITE 5 LINES

       WRITE 5 LINES

       WRITE 5 LINES

       WRITE 5 LINES


MAX-MIN DETECTOR 10/10/73 THE DETECTOR HAS BEEN IMPLEMENTED AS A HARDWARE DEVICE USING STANDARD OPERATIONAL AMPLIFIERS, FET SWITCHES, AND LOGIC ELEMENTS. IT ALSO EXISTS AS A FOCAL 12 PROGRAM THAT OPERATES ON STORED DIGITAL DATA. A MAXIMUM IS DEFINED AS THE LARGEST VALUE PRECEDED BY A VALID MINIMUM AND FOLLOWED BY A DESIGNATED DROP. SIMILARLY A MINIMUM MUST BE PRECEEDED BY A VALID MAXIMUM AND FOLLOWED BY A DESIGNATED RISE. A DESIGNATED DROP IS A FUNCTION OF THE SIZE OF A POTENTIAL MAXIMUM PLUS SOME CONSTANT PLUS ANY OTHER PARAMETER THAT IS CONVENIENT. THE INFLUENCE OF THE DESIGNATED DROP MODIFYING THE RELATIVE IMPORTANCE OF COMPONENTS OF THE DESIGNATED DROP ADAPTS THE DETECTOR FOR THE SPECIAL CHARACTERISTICS OF THE DATA. 1. A SMALL CONSTANT PLUS 80% OF THE POTENTIAL MAXIMUM-THE DETECTOR IS NOW MORE SENSITIVE OT SMALL PEAKS NEAR THE BASELINE THAN LARGE PEAKS. THIS IS A CHARACTERISTIC SUITABLE FOR ANALOG OUTPUT FROM SCANNING MASS SPECTROMETERS. IF THE CONSTANT WERE NOT PRESENT THE SYSTEM WOULD BBECOME TOO SENSITIVE AND BEGIN TRIGGERING ON BASELINE NOISE. 2. A CONSTANT ALONE -THE DETECTOR IS NOW INDEPENDENT OF ANY FIXED BASELINE.EVERY MINIMUM IS THE REFERNCE LEVEL FOR A POTENTIAL MAXIMUM AND VICE VERSA. THIS CHARACTERISTIC IS SUITABLE FOR USE WITH ANALOGS OF BLOOD PRESSURE AND THE ELECTROCARDIOGRAM. WRITE 5 LINES WRITE 5 LINES WRITE 5 LINES WRITE 5 LINES WRITE 5 LINES



Feel free to contact me, David Gesswein djg@pdp8online.com with any questions, comments on the web site, or if you have related equipment, documentation, software etc. you are willing to part with.  I am interested in anything PDP-8 related, computers, peripherals used with them, DEC or third party, or documentation. 