File SKDEMO.TX (text file)

Directory of image this file is from
This file as a plain text file

          SKDEMO.TX   11/1/73

......&TSPANSULE

USED TO ESTIMATE THE EQUIVALENT DOSAGE OF A DRUG ADMINISTERED
IN SPANSULE FORM.

INPUT - THE OPERATOR KEYS IN A DOSAGE SCHEME OF UP TO EIGHT
TABLETS OF VARYING SIZE. TABLWTS ARE ADMINISTERED ON THE HOUR AND
THE TOTAL TIME SPAN IS CONSIDERED AS 24 HOURS OR SOME MULTIPLE.
ADDITIONAL INPUT COMES FROMDATA FILE  %SPANSULE  WHICH CONSISTS
OF DOCUMENTATION, A MASTER RESPONSE CURVE, AND A SPANSULE RESPONSE
CURVE.

OUTPUT - THE PRINCIPAL OUTPUT IS THE COMPUTER DISPLAY SCOPE.
ALL THE FOLLOWING ITEMS ARE DISPLAYED AT THE SAME TIME.
      1. SPANSULE RESPONSE CURVE MARKED WITH DIAMOND SYMBOLS.
      2. COMPUTED RESPONSE MARKED WITH + SYMBOLS.
      3. TIME MARKERS EVERY FOUR HOURS ON THE BOTTOM OF THE DISPLAY.
      4. DOSAGE SCHEME.
ALSO, THE OPERATOR CAN DIRECT THE COMPUTER TO PRINT OUT A TABLE
OF VALUES OF COMPUTED RESPONSE.
EVERY TRAIL RUN IS PRECEDED BY A PRINTOUT OF THE TIME DOSE TABLE 
MOST RECENTLY ENTERED.





......&DSPANSULE

USED TO ALTER OR COMPLETELY CHANGE THE DATA SETS  FOR &TSPANSULE.

OUTPUT - MODIFIED DATA SETS ON LIBRARY FILE  %SPANSULE.

INPUT - OPERATOR CAN CHOOSE TO ALTER THE DRUG
REFERENCE CURVE OR THE SPANSULE CURVE. THE REFERENCE CURVE IS
SET FOR 48 VALUES AT 1/2 HOUR INTERVAL TO MAKE UP 24 HOURS.
ALL OR PART OF THE CURVE MAY BE MODIFIED.  THE SPANSULE CURVE
REQUIRES 24 VALUES.THE CURVE MUST BE PUT IN AS A COMLETE SET.



......&BRONCHO

ACCEPTS VALUES FOR SYSTOLE,DIASTOLE, HEART RATE, AND AREA, AND
RETURNS FORMATTED SUMMARY REPORTS. REAL TIME OPERATION.

OUTPUT - SHORT AND LONG FORM REPORTS OF AVERAGES AND DERIVED DATA.
UPON OPERATOR COMMAND THE THE REPORT FORMAT CAN BE SWITCHED OR 
THE AMOUNT OF DATA AVERAGED CAN BE ALTERED. 

INPUT - NORMAL INPUT IS FROM AUTOMATIC LOGGING APPARATUS VIA 
TELEPHONE LINE TO A REMOTE COMPUTER. THE LABORATORY TECHNICIAN
HAS THE OPTION OF KEYBOARD INPUT FOR CONTROL OF THE PROGRAM.
THE COMPUTER STOPS INPUT FROM THE AUTOMATIC LOGGER DURING PRINTOUTS.
 FOR DEMONSTRATIONS, THE INPUT CAN BE SIMULATED BY THE TELETYPE
KEYBOARD. THE FORMAT IS    2DIGITS FOR DEVICE CODE AND THREE DIGITS
FOR VALUE. THE FIVE DIGITS ARE FOLLOWED BY A CARRIAGE RETURN
TO COMPLETE THE LINE.
        00XXX   SYSTOLE
        01XXX   DIASTOLE
      02XXX   HEART RATE

   ALWAYS IN THE ABOVE ORDER.
        03XXX   AREA
       ANYTIME

        08000    LONG FORMAT
        08XXX    SHORT FORMAT
          ANYTIME

        09XXX   AMOUNT OF DATA SETS TO AVERAGE.

SKDEMO.TX 11/1/73 ......&TSPANSULE USED TO ESTIMATE THE EQUIVALENT DOSAGE OF A DRUG ADMINISTERED IN SPANSULE FORM. INPUT - THE OPERATOR KEYS IN A DOSAGE SCHEME OF UP TO EIGHT TABLETS OF VARYING SIZE. TABLWTS ARE ADMINISTERED ON THE HOUR AND THE TOTAL TIME SPAN IS CONSIDERED AS 24 HOURS OR SOME MULTIPLE. ADDITIONAL INPUT COMES FROMDATA FILE %SPANSULE WHICH CONSISTS OF DOCUMENTATION, A MASTER RESPONSE CURVE, AND A SPANSULE RESPONSE CURVE. OUTPUT - THE PRINCIPAL OUTPUT IS THE COMPUTER DISPLAY SCOPE. ALL THE FOLLOWING ITEMS ARE DISPLAYED AT THE SAME TIME. 1. SPANSULE RESPONSE CURVE MARKED WITH DIAMOND SYMBOLS. 2. COMPUTED RESPONSE MARKED WITH + SYMBOLS. 3. TIME MARKERS EVERY FOUR HOURS ON THE BOTTOM OF THE DISPLAY. 4. DOSAGE SCHEME. ALSO, THE OPERATOR CAN DIRECT THE COMPUTER TO PRINT OUT A TABLE OF VALUES OF COMPUTED RESPONSE. EVERY TRAIL RUN IS PRECEDED BY A PRINTOUT OF THE TIME DOSE TABLE MOST RECENTLY ENTERED. ......&DSPANSULE USED TO ALTER OR COMPLETELY CHANGE THE DATA SETS FOR &TSPANSULE. OUTPUT - MODIFIED DATA SETS ON LIBRARY FILE %SPANSULE. INPUT - OPERATOR CAN CHOOSE TO ALTER THE DRUG REFERENCE CURVE OR THE SPANSULE CURVE. THE REFERENCE CURVE IS SET FOR 48 VALUES AT 1/2 HOUR INTERVAL TO MAKE UP 24 HOURS. ALL OR PART OF THE CURVE MAY BE MODIFIED. THE SPANSULE CURVE REQUIRES 24 VALUES.THE CURVE MUST BE PUT IN AS A COMLETE SET. ......&BRONCHO ACCEPTS VALUES FOR SYSTOLE,DIASTOLE, HEART RATE, AND AREA, AND RETURNS FORMATTED SUMMARY REPORTS. REAL TIME OPERATION. OUTPUT - SHORT AND LONG FORM REPORTS OF AVERAGES AND DERIVED DATA. UPON OPERATOR COMMAND THE THE REPORT FORMAT CAN BE SWITCHED OR THE AMOUNT OF DATA AVERAGED CAN BE ALTERED. INPUT - NORMAL INPUT IS FROM AUTOMATIC LOGGING APPARATUS VIA TELEPHONE LINE TO A REMOTE COMPUTER. THE LABORATORY TECHNICIAN HAS THE OPTION OF KEYBOARD INPUT FOR CONTROL OF THE PROGRAM. THE COMPUTER STOPS INPUT FROM THE AUTOMATIC LOGGER DURING PRINTOUTS. FOR DEMONSTRATIONS, THE INPUT CAN BE SIMULATED BY THE TELETYPE KEYBOARD. THE FORMAT IS 2DIGITS FOR DEVICE CODE AND THREE DIGITS FOR VALUE. THE FIVE DIGITS ARE FOLLOWED BY A CARRIAGE RETURN TO COMPLETE THE LINE. 00XXX SYSTOLE 01XXX DIASTOLE 02XXX HEART RATE ALWAYS IN THE ABOVE ORDER. 03XXX AREA ANYTIME 08000 LONG FORMAT 08XXX SHORT FORMAT ANYTIME 09XXX AMOUNT OF DATA SETS TO AVERAGE.



Feel free to contact me, David Gesswein djg@pdp8online.com with any questions, comments on the web site, or if you have related equipment, documentation, software etc. you are willing to part with.  I am interested in anything PDP-8 related, computers, peripherals used with them, DEC or third party, or documentation. 

PDP-8 Home Page   PDP-8 Site Map   PDP-8 Site Search